Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arq. bras. med. vet. zootec. (Online) ; 73(4): 955-965, Jul.-Aug. 2021. tab
Article in English | LILACS, VETINDEX | ID: biblio-1285270

ABSTRACT

The aim of this study was to evaluate the reasons of quality deviation of a concentrate from a predefined standard. Five treatments were established: T1 - Control, standard concentrate formulation (SCF); T2 - PXMore5, SCF with more 5% vitamin-mineral premix (VMP); T3 - PXLess5, SCF with less 5% VMP. All three treatments used a 400kg batches in an INTECNIAL mixer; T4 - FeedMixer, SCF using a 4,000kg batch in an IMOTO mixer; T5 - PremixMixer, SCF using a 1,200kg batch in an MUYANG mixer. For each treatment, bags of 20 kg were stored in three storage places for four months. Water activity of concentrate was affected by temperature and air relative humidity in different storage places. Regarding the kind of mixer, the greatest variation in concentration of crude protein, mineral residue, copper, zinc, and selenium was observed in the PremixMixer. Adjustments are imperative in the handling and use procedures of this kind of mixer to meet the quality requirements required in the concentrate production. Analyzing the effect of the mineral-vitamin premix level, no difference could be defined with the evaluated parameters.(AU)


O objetivo deste estudo foi avaliar as razões do desvio de qualidade de um concentrado de um padrão predefinido. Foram estabelecidos cinco tratamentos: T1 - controle, concentrado com formulação padrão (CFP); T2 - PXMais5, CFP com 5% a mais de vitaminas e minerais da pré-mistura (PVM); T3 - PXMenos5, CFP com 5% a menos de PVM. Todos esses três tratamentos utilizaram lotes de 400kg em um misturador INTECNIAL; T4 - FeedMixer, CFP usando um lote de 4.000kg em um misturador IMOTO; T5 - PremixMixer, CFP usando um lote de 1.200kg em um misturador MUYANG. Para cada tratamento, sacos de 20kg foram armazenados em três ambientes distintos por quatro meses. A atividade de água do concentrado foi afetada pela temperatura e umidade relativa do ar em diferentes locais de armazenamento. Em relação ao tipo de misturador, a maior variação na concentração de proteína bruta, resíduo mineral, cobre, zinco e selênio foi devido ao PremixMixer. Ajustes são imperativos nos procedimentos de manuseio e uso desse tipo de misturador para atender aos requisitos de qualidade exigidos na produção de concentrado. Ao se analisar o efeito do nível da pré-mistura de vitaminas e minerais, nenhuma diferença pôde ser definida com os parâmetros avaliados.(AU)


Subject(s)
Animals , Swine , Nutrients/administration & dosage , Animal Feed/analysis , Selenium , Thyroxine , Triiodothyronine , Vitamins , Zinc , Copper
2.
Braz. j. pharm. sci ; 51(2): 273-284, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755070

ABSTRACT

This study aims at developing an analytical procedure capable of quantifying the ferric oxide present in the mixture of ferric oxide/lactose monohydrate (0.4% w/w). The analytical procedure was checked for specificity, linearity, precision (system repeatability, procedure repeatability and intermediate precision), accuracy, stability of solutions and robustness of the procedure. The concentration of Fe (III) was determined by spectrophotometry at 480 nm based on calibration curves. The specificity was verified. The linearity was obtained in the range of 11.2 to 16.8 µg of ferric oxide/mL. The relative standard deviation (RSD) of the system repeatability, procedure repeatability and intermediate precision, were not more than 2%. The RSD of the accuracy values were less than 0.75%. The stability of the samples was checked over a 24 hours assay. In the robustness evaluation, the wavelength and the concentration of hydrochloric acid varied. The maximum absorbance deviation due to wavelength variation was 0.14 percent, and the maximum deviation due to the hydrochloric acid concentration variation was 2.4%, indicating that the concentration of hydrochloric acid is critical to the analysis of ferric oxide. The procedure developed was validated and is suitable to the performance qualification of powder mixers..


O objetivo deste trabalho foi desenvolver um método analítico capaz de quantificar o óxido férrico presente na mistura óxido férrico/lactose monoidratada (0,4% w/w). Verificou-se a especificidade, linearidade, precisão (repetibilidade do sistema, repetibilidade do método e precisão intermediária), exatidão, estabilidade das soluções e robustez. A concentração de Fe(III) foi determinada por espectrofotometria em 480 nm com base em curvas de calibração. Verificou-se a especificidade verificada. A linearidade foi obtida na faixa de 11,2 a 16,8 µg de óxido férrico/mL. O desvio padrão relativo (DPR) da repetibilidade do sistema, método e precisão intermediária foram inferiores a 2%. Os valores de DPR da exatidão foram inferiores a 0,75%. A estabilidade das amostras foi verificada ao longo de 24 horas de ensaio. Na avaliação da robustez variou-se o comprimento de onda e a concentração de ácido clorídrico. O desvio máximo de absorbância ao se variar o comprimento de onda foi de 0,14%, enquanto que para a concentração de ácido clorídrico o desvio foi de 2,4% para a concentração de 0,8 M. Assim, a concentração de ácido clorídrico é crítica para a análise de óxido férrico. O método desenvolvido foi validado e é adequado à qualificação do desempenho de misturadores de pós e granulados...


Subject(s)
Humans , Dust , Dough Mixers/methods , Ferrosoferric Oxide/analysis , Chemical Phenomena/methods , Quality Control
SELECTION OF CITATIONS
SEARCH DETAIL